Doyon JAOP12SL User Manual Page 18

  • Download
  • Add to my manuals
  • Print
  • Page
    / 56
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 17
A-15
MANUAL MODE
This mode is used to work one step program.
Press on (Start) when the oven is ON, the oven will run on preheat mode at the manual mode set
point (by exception if you select a cook program referred in the PROGRAM MODE section).
TEMPERATURE FUNCTION
To change the temperature set point, press and hold for 3 sec. on . When
appears on the left
side of the display, press on / (Up / Down) to select the desired temperature set point. The
new set point will be automatically saved after 3 seconds.
TIMER FUNCTION
To change the time setting, press and hold for 3 sec. on
.
When
appears on the left side of
the display, press on
/ (Up / Down) to select the desired time setting. The new time setting
will be automatically saved after 3 seconds.
If time is less than 60 minutes, it will be displayed as MM.SS
If time is 60 minutes or more, it will be displayed as HH:MM
The fan is always in function, but you can delay the fan for 5 min. (electric oven) or
30 sec. (gas oven) by pressing the Delay key . After this delay, the fan will run
normally.
By pressing a second time on the key before the end of the delay, the fan will remain in function.
Steam output can be turned on only if oven’s temperature >= steam threshold
(300°F /149°C).
Steam output can be turned on only if fan is on PULSE or ON.
Pulse Steam
: will turn on and off the steam output continuously if pressed again.
Shot steam : steam output is turned on for duration of preset time.
Note: Steam and Pulse-Steam in Manual Mode will force Fan On.
This function is available only with ovens using a rotating rack. This function allows to start and
stop the rack.
Food Probe in Manual Mode
When activated, the food probe temperature can only be used in mode MONITOR
ONLY. This will indicate the internal food temperature, not the cooking. To control
cooking, use the Programming mode.
FAN DELAY FUNCTION
STEAM GENERATION FUNCTION
FUNCTION CHARIOT