Doyon JAOP12SL User Manual Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 56
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
A-16
PROGRAM MODE
This mode is used to program a Cook Recipe.
Cook Program structure
A cook program consists of a name as well as a number of steps. The name is pre-programmed into
the unit (each name can have up to 30 characters). Each step has the following programmable
parameters:
Oven temperature: the oven set point for this step.
Food temperature: the food temperature at which this step will end.
Time: the time duration for the current step.
Steam: the time steam is injected into the oven at the beginning of the step.
Fan: fan mode.
Aux.: on or off during step (only programmable via PC).
Rack: on or off during step.
Step End: user action needed at the end of step.
Programming
LED/Display
1
st
line displays currently selected parameter’s value.
2
nd
line displays current step.
Keys
To program or modify a recipe program, select the recipe name first, press and hold for 3
seconds on the Program key. This will give you access to the recipe program. If no
change is made in the recipe during more than 5 seconds, the controller will exit the recipe
program mode by itself and go back to standby mode.
All parameters can be programmed in any order within a step.
To program or modify a recipe, follow these steps :
Use the parameter keys (Temperature, Time, Steam, Pulse-Steam, Fan, Rack, or Step End) to
display and change its value.
Temperature key is used twice to program 2 parameters: Oven Set Point and Food
Temperature.
Use the Up / Down keys to change the current parameter.
Use the Previous / Next keys to change the current step number.
If Step End key is set to LAST
, it is considered to be the last step of the program even though
more steps may follow in the program.
After last step is programmed, hold the Program key for 3 seconds to exit programming
mode.
Valid programming ranges
Temperature
50-500°F / 10-260°C
Food Temperature
125-225°F / 51-107°C, must be enabled in Low-level programming to be used.
Time
Time is programmed in HH:MM.SS
Time can be programmed at any value between 00:00 minimum and 12:00 maximum.
Default is 00:00 for all steps / programs.